ICC ANSL A117.1-2003 PDF

ICC ANSL A117.1-2003 PDF

Trademarks: “ICC,” the International Code Council logo and “Accessible and Usable Buildings and Facilities (ICC/ANSI Al )” are trademarks of the. This Accessible and Usable Buildings and Facilities (ICC Al) is a The edition of ANSI Standard A presented the first criteria for accessibil. Major changes/additions from ICC ANSI A – found in the edition of A 1. ICC ANSI. A – Section. ICC ANSI A –

Author: Tor Shakam
Country: Eritrea
Language: English (Spanish)
Genre: History
Published (Last): 28 November 2005
Pages: 191
PDF File Size: 10.24 Mb
ePub File Size: 17.59 Mb
ISBN: 272-9-32868-406-8
Downloads: 59675
Price: Free* [*Free Regsitration Required]
Uploader: Kijas

Where enhanced reach range is required at lavato- ries, faucets and soap dispenser controls shall have a reach depth of 11 inches mm maximum or, if automatic, shall be activated within a reach depth of 1 1 inches mm maximum. Projections into the clear opening width between 34 inches a1117.1-2003 and 80 inches mm above the floor shall not exceed 4 anzl mm.

A parcel of land bounded by a property line or a designated portion of a public right-of-way. The National Easter Seal Society and the President’s Com- mittee on Employment of People with Disabilities became members of the Secre- tariat, and the edition was reaffirmed in Where a for- ward approach is provided, the distance from the front edge of a counter within ansll enclo- sure to the face of the telephone shall be 20 inches mm maximum.

Wheelchair accessible compartments shall comply with Section The turning space shall be a circular space with a inch mm minimum diameter. The rear edge of the “L”.

Car and van parking spaces shall have an adjacent access aisle complying with Section Section of this standard provides criteria for Type B units. Elevator cars shall provide a clear floor area of 42 inches mm minimum in width, xnsl 54 inches mm minimum in depth.

In alternate roll-in showers with the controls and hand shower located on the back wall opposite the seat, the a117.12003 and hand shower shall be located within 15 inches mmleft or right, of the centerline of the seat. Where the reach depth exceeds 20 inches mmthe high forward reach shall be 44 inches 1 mm maximum, and the reach depth shall be 25 inches mm maximum.

  FOSCOLO ULTIME LETTERE DI JACOPO ORTIS PDF

ICC/ANSI A – Accessible and Useable Buildings and Facilities

Tactile characters shall comply with Section The adjacent surfaces at transitions at curb ramps to walks, gutters and streets shall be at the same level. The high forward reach shall be 48 inches mm maximum where the reach depth is 20 inches mm maximum. Sides of ramp landings having a vertical drop-off of V 2 inch 13 mm maximum within 1 inches mm horizontally of the mini- mum landing area.

Where signs indi- cate that elevators do not serve all landings, signs in tactile characters complying with Section An entry 36 inches 91 idc mm minimum in width shall be provided at one end of the inch mm width of the compartment. The clear a117.-12003 space shall not be obstructed by bases, enclosures, or seats. Spaces and elements specifically designed for use primarily by people 12 years icc and younger.

Detectable warning sur- faces in interior locations shall differ from adjoining walking surfaces in resiliency or sound-on-cane contact. An adjustable-height shower head mounted on a verti- cal bar shall be installed so as to not obstruct the use of grab bars. For bathtubs with permanent seats, grab bars com- plying with Section Accessible stairs shall comply with Section Characters shall be sans serif.

Numeric keys shall be arranged in a key ascending or descending a117.1-203 phone keypad layout.

2003 ICC Accessible and Usable Buildings and Facilities

The rear grab bar shall be permitted to be 24 inches mm minimum in length, centered on the water closet, where wall space does not permit a grab bar 36 inches mm minimum in length due to the location of a recessed fixture adjacent to the water closet. Doors shall not swing into the clear floor space or clearance for any fixture.

Where toe clearance is required at an element as part of a clear floor space, the toe occ shall extend 17 inches mm minimum beneath the element. Where a permanent seat is provided at the head end of the bathtub, the clearance shall extend 12 inches mm minimum beyond the wall at the head end of the bathtub.

  DAP-2553 MANUAL PDF

ANSI A117.1 (2003): Accessible and Usable Buildings and Facilities

In trans- fer-type and alternate roll-in-type showers, the seat shall extend along the seat wall to a point within 3 inches 75 mm of the compartment entry. Where a high forward reach is over an obstruction, the clear floor space jcc extend beneath the element for a distance not less than the required reach depth over the obstruction. Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight. Should a figure appear to illustrate criteria that differ with the text of the Standard, the criteria stated in the text govern.

The clearance between the car platform sill and the edge of any hoistway landing shall be 1 V 4 inches 32 mm maximum. The bottoms of diagonal curb ramps shall have 48 inches mm minimum clear space outside active traffic lanes of the roadway.

State Building Code – ICC/ANSI A Code Interpretations

Detectable warning sur- faces a17.1-2003 be standard within a building, facility, site, or complex of buildings. Detectable warning surfaces shall contrast visually with adjacent surfaces, either light-on-dark or dark-on-light. The down scan button shall sequentially select floors below the current floor.

Elevator car controls shall comply with Sections Treads shall be 1 1 inches mm minimum in depth. Please visit the ICC website at www. Door closers and door stops shall be per- mitted to be 78 inches 1 mm minimum above the floor. Floor designa- tions shall be provided in tactile characters complying with Section